Performance of Delta4 Phantom+ using Flattening-Filter and Flattening Filter-Free beams
Abstract
En
The goal of this study was to evaluate the performances of the new pre-treatment system Delta4 Phantom+ in terms of a stable and sensitive tool for achieving a reliable verification. Delta4+ was evaluated for verification with 6FFFMV beams using static beam arrangement. The accelerator output was monitored with the ionization chamber. The device was tested for dose-rate dependence, linearity and stability using its daily output correction. The response of Delta4+ was evaluated for energy 6FFFMV, measuring the gamma index of four Volumetric Modulated Arc Therapy (VMAT) plan. The response of Delta4+ as a function of accelerator dose rate is in agreement with the ionization chamber with a difference smaller than 0,1%. The output is constant for different MU. VMAT plan analysis show values within 98,3%-100% with a threshold of 3%-3mm, while with a threshold of 2%-2mm the values are within 93,5%-97,5%. Delta4+ is an accurate device. For all the measurements made, uncertainties below 1% were obtained.
It
Lo scopo di questo studio è stato quello di valutare la risposta in termini di stabilità e sensibilità del nuovo sistema pre-trattamento Delta4 Phantom+. La risposta del sistema è stato studiata utilizzando fasci di fotoni da 6MVsenza filtro di flattening (6FFFMV). L'output dell'acceleratore è stato monitorato con una camera a ionizzazione. La dipendenza dal dose rate, la linearità e la stabilità sono state verificate utilizzando il fattore di correzione giornaliera fornito dal sistema. La risposta è stata verificata su 4 piani di trattamento con tecnica VMAT. La risposta del Delta4+ al variare del dose rate è in accordo con quella della camera a ionizzazione con una scarto minore dello 0.1%. La risposta al variare delle UM è costante con una differenza entro lo 0.4%. L'analisi dei piani VMAT mostra valori di indice gamma per soglia 3%-3mm compresi tra 98.3%-100%, mentre per 2%-2mm i valori sono tra 93,5%-97,5%. Il Delta4+ risulta essere un sistema accurato in quanto l'incertezza ottenuta su tutte le misure non supera l'1%.
The goal of this study was to evaluate the performances of the new pre-treatment system Delta4 Phantom+ in terms of a stable and sensitive tool for achieving a reliable verification. Delta4+ was evaluated for verification with 6FFFMV beams using static beam arrangement. The accelerator output was monitored with the ionization chamber. The device was tested for dose-rate dependence, linearity and stability using its daily output correction. The response of Delta4+ was evaluated for energy 6FFFMV, measuring the gamma index of four Volumetric Modulated Arc Therapy (VMAT) plan. The response of Delta4+ as a function of accelerator dose rate is in agreement with the ionization chamber with a difference smaller than 0,1%. The output is constant for different MU. VMAT plan analysis show values within 98,3%-100% with a threshold of 3%-3mm, while with a threshold of 2%-2mm the values are within 93,5%-97,5%. Delta4+ is an accurate device. For all the measurements made, uncertainties below 1% were obtained.
It
Lo scopo di questo studio è stato quello di valutare la risposta in termini di stabilità e sensibilità del nuovo sistema pre-trattamento Delta4 Phantom+. La risposta del sistema è stato studiata utilizzando fasci di fotoni da 6MVsenza filtro di flattening (6FFFMV). L'output dell'acceleratore è stato monitorato con una camera a ionizzazione. La dipendenza dal dose rate, la linearità e la stabilità sono state verificate utilizzando il fattore di correzione giornaliera fornito dal sistema. La risposta è stata verificata su 4 piani di trattamento con tecnica VMAT. La risposta del Delta4+ al variare del dose rate è in accordo con quella della camera a ionizzazione con una scarto minore dello 0.1%. La risposta al variare delle UM è costante con una differenza entro lo 0.4%. L'analisi dei piani VMAT mostra valori di indice gamma per soglia 3%-3mm compresi tra 98.3%-100%, mentre per 2%-2mm i valori sono tra 93,5%-97,5%. Il Delta4+ risulta essere un sistema accurato in quanto l'incertezza ottenuta su tutte le misure non supera l'1%.
DOI Code:
10.1285/i9788883051555p59
Full Text: PDF